DIALER
PROGRAMMING
(~)
*34
*35
*36
*37
*36
ALARM BELL TIMEOUT
n
This field determineswhether the external sounder will shut off after
time allotted,or continueuntil manually turned off. Enter as follows
O= No timeout 1 = 4 rnin (default); 2 = 8 ti, 3 = 12 min.
Alarm bell timeout must be set for a
minimum of 4 min (“1=)
for UL installations.
ZONE TYPE
01 ENTRY DELAY Partition1 Partition2
Systemwill wait the time allottedbeforesounding alarm upon
entering. May be selectedindividually for eachPartition.
o= Oseconds 2 =30 seconds 4 =60 seconds
1 =20 seconds 3 =45 seconds 5 =90 seconds
Default is 2 (30 seconds).Entry delay must be set for a maximum
of 20 seconds in UL installations.
Zone~ 02 Entry Delay= ZoneType 01 Entry Delay+ 30 seconds.
(EXIT delays= Zonetype 01 En@ delay plus 40 seconds).
AUDIBLE EXIT WARNING
Partition1
Psrtition2
If enabled,this field provides exit warning sound when armed AWAY
it canbe selectedfor either or both Partitions.
Warning sound consistsof slowcontinuous beepsuntil last 5 seconds,
when it changes to fast beeps. The warning sound will end at the
termination of Exit time.
O= no; 1 = yes.Default is 1.
CONFIRMATION OF ARMING DING Part%1
%rt?n2
Enter 1 (in either or both Partitions) to enable l/2 second external
alarm sounding“ding” when closingreport goesin, or at the end of exit
delay.Odisablesthe “iii@’ (default).
POWER UP IN PREVIOUS STATE
•1
Enter 1 for Yes (default) if, upon power-up, you want the system to
assumethe systemstatusprior to power down. Enter O if you want the
systemto alwayspowerup in a disarmed state.
When the systempowersup armed, an alarm will occur1 minute after
arming if a zoneis faulted. Must be *1” for UL installations.
Note that if the previous state was armed AWAY or STAY, the system
will not respondto sensorchangesfor 1 minute, which allowstime for
sensorssuchasPIRs to stabilize.
Enter up- to- the
number of digits
shown. Do not fill
unused spaces.
Enter O-9,
# + 11 for ‘*’
# + 12 for%’
# + 13 for a pause
(2.5 sees)
PABX ACCESS CODE (See Box at Left)
Ill
Enter up to 4 digits if PABX is needed to accessan outside line. If
fewer than 4 digits are needed to be entered, exit by pressing * and
next field number (e.g.,41). To clearenlries horn field, press ZO*.
PRIMARY PHONE No. (See Box at Left)
I
1111111111!
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing
*ad na field n~ber (e.g.,42).
TO clear entries from field, press
%1*.
Note: Back-up reporting (8 calls are made to the secondary phone
number if no kiss-off is received after 8 attempts to the primary
number) is automaticonly if there is a second- phone number (field
*42).
SECONDARY PHONE No. (See Box at Left)
11111111111
Enter up to 12 digits. If fewer than 12 digits entered,exit by pressing
* and next field number (e.g., 43). To clear entries from field, press
*42*. SeeNote above,also.