Ganaral Information
An Audio Alarm VerMcation (Alv) module, such as the Eagle 124~ is an
add-on accessorythat permits voicedialog between en operator at a central
station and a person at the alarm installation, for the purpose of alarm
vetication.
After all messageshave been sent during a reporting sessionto the primary
phone number, the contiolwill t@ger the AAV if at least one of the messages
was an alarm report. If ContactID format is selectedfor the primary phone
number, the controlwill send a “listen-in to follow” message,which signals
the 685 to hold the phoneconnectionfor 1 minute.
Once the digital messageis “kissedoff, the control will give up the phone
line to the AIV module,without breaking connectionwith the central station.
At this time, W sirens and all continuouskeypad soundsin zdlpartitions will
be shut Off.
we Connations
The method used to trigger AAV is via the use of a 4204 or 4229 relay
module, as shownin the AAV connectiondiagrams that follow (one diagram
for connectionswhen a 4285VoiceModule is usecl the other when the 4285 is
not used).
1.
2.
3.
4.
5.
6.
With at least one 2-line Alpha keypad (5137AD or 6139) connectedto the
Partition 1 terminals, power up the system. If you had previously
connectedthe AC transformer to the controlpanel, you need only plug in
the transformer (to 120VAC outlet)to powerup the system.
Enter the programming mode by keying the following on the Alpha
keypad Installer code (41 12) + 800.
Press al. OPTION SELECTION. Enter “4” for AAV monitoring.
Enter “O”for UL installations.
Relay programming in field *8O: Do not program anything for
Relay #1.
Exit the prob~g
modeby keying *99.
Unplug the AC transfomner.