Press *48 REPORT FORMAT, PRIMARY/SECONDARY
Primary
❑
Secondary ❑
Determines which format is to be used to report to the central
station.
O= 3+1; 4+1 ADEMCO Lo SpeedStandard (this is the default)
1 = 3+~ 4+1 Rd.iOfiCS Standard
2 = 4+2 ADEMCO Lo SpeedStandard
3 = 4+2 Radionicsstandard
6 = 4+2 ADEMCO Express
7 = ADEMCO ContactID Reporting
8 = 3+1; 4+1 ADEMCO Lo SpssdExpanded
9 = 3+1; 4+1 RadionicsExpanded
(Enter *as the 4th digit of* 43 through* 46, if 3+1 dialer report
ing is to be used.)
Note: The maximum number of alarm and alarm restorereports
during onearmed periodis determinedby field *93.
Press *49
SPLITYDUAL REPOR~G
El
Enter Oto disable(Backupreport only). This is the default.
To PRIMARY
TO SECONDARY
1= Alarms, Restore,Cancel
Others
2 = All exceptOpen/Close,Test
Open/Close,Test
3
=
Alarms, Restore,Cancel
All
4= All exceptOpen/Close,Test
All
5
= All
Au
Press *50
Press *51
%eSS * 52
Press *53
15-SECOND DIALER DE3AY, BURGLARY
c1
Enter Ofor no, or 1 for yes.Default is O (no delay).
titer “()”for IJL inStall.StiOnS.
PERIODIC TEST REPORT
•1
Selectthe desiredtestreport interval.
O= none 1 =24 hours; 2 = weeld~ 3 = 30 days. Default is O
(none). Test Report Codeenteredin field* 64 is sent.
Reportswith Partition 1 SubscriberNo.
TEST IUIPORT OFFSET
❑
This is the time to first report after exitingfrom programming or
downloading.
O= 24-houq 1 = 6 hours; 2 = 12 hours; 3 = 18 hours. Default is 2.
SESCOMRADIONICS SELECT
u
O= Radionics (O-9, B-F reporting)
1 = SESCOA (O-9 only reporting)
SelectOfor all otherfon.nats.Default is O.