Rogmmdng iiard-Wmed Zones
1.
With at leastone 2-line Alpha keypad (5137AD or 6139) connectedto the
Partition 1 keypad terminals on the control, power up the system
temporarily. If you had previouslyconnectedthe AC transformer to the
contxolpanel,you need only plug in the transformer (to 120VAC outlet)to
powerup the system.
2. Enter the progr
amming mode by keying the following on the Alpha
keypa& Inetallerwde (4112) +S+O+0.
Note that it is not possibleto enter the programming mode if Partition 2
is in an armed state.
3. Press *56. Note that this is an interactiveprogramming mode.You will
use it to program zone numbers, zone ~es, partition numbers, alarm
report codes,and to program responsetimes for hard-wired zones.
II
Enter Zn Num.
(00 = Quit) 01
II
~ical summarydisplay
t
*
II
ZniTPRCln RT
O2O31OOHW1
I
.L ZoneNumber
II
02 Zone Type
Perimeter
03
II
ZoneTypeT
Upon entering *56 mode, this prompt will be
displayed. Enter the first zone number that
you wish to program (or [0][0] to exit zone
pro~g). H YOUare S- ~th zone 2,
enter“02”. Ress *to continue.
A summary display will appear, showing the
presentstatusof that zone’sprogramming.
Zn = zonenumber;
ZT = zone@pq
P = partition to which zoneis aasigne~
RC = report codefor that zon~
In= input type of zon~
RT = responsetime for that zone.
Values displayed are currently programmed
values.
If it is programmed satisfactorily, press [#] to
back up one step and enter the next zone
number, if desired.
If you want to change a zone’s programming,
press[*]. A prompt for ZoneType will appear.
Each zonemust be assigneda zone type, which
defies the way in which the system responds
to ikultein that zone.A detailed explanation of
eachzone type is provided in %esponse Type
Definitions”in
Section 18. ZONE RESPONSE
TYPE DEFINITIONS.
Enter the desired zone type code, as listed
below.
00= ZoneNotUsed
01= Entry/Exit#1
02= Entry/Exit#2
03= Perimeter
04= InteriorFollower
07= 24Hr Audible
08=24 HrAux
09= Fire(w/verif.)*
10= Ipteriorw/Delay
23= NoAlarm
05= TroubleDay/AlarmNight
Response
06= 24Hr Silent
24. SilentBurglary
* The%ritkation” featureis onlyactivewhenzone
type09is assignedtohard-wiredzone1.
When the display showsthe zone type you want,