ZoneList Displays4
b
●
●
●
●
●
To stop the Device action and turn off the lamp, we do not want to use a
restoreof eny zone,so a “O will be programmed for the
Restore of Zone List
(zL). We will use a manual
entry of User Code+ [#] + [8] + Device # to
turn off. Therefore,wedo not need to program a STOP event.
Press[*I to continue.
The systemwill display a summary screenfor the START progr
amming for
device01. Ress [*I to continue.
The systemwill display a summary screenfor the STOP progr
emming for
device01. Press[*I to continue.
The systemwill displaythe “2UO? prompt. Enter 1 for yes.
The
Enter Device No. prompt for the next zone will be displayed.
Press00 and then [*I to etit the *8O mode.
Now use %1 ZoneList modeto program the 3 specificzonesin ZoneList 1.
Press
*81. (Zone Lists for Output Devices]. This interactive mode is
applicableonly if you have programmed *O mode.
Referto the Programming
Form worksheetfor *81 Mode.
Upon keying *81, this screenwill appear. Enter the ZoneList Number 01,02,
or 03 to program (or 00 to end theseenties). Ress the [*] key to advance.
In the followingdisplays,zonelist 01 has been selectedfor programming.
Enter each zone number to add to the zone list by first entering the zone
number, then the [*I key (example,01*, 02*, 03*). ~er ~ zonesdesired~
entered,press00 to advance.
To deletethe zonelist, enter 1 (Yes). AU zonesin the zone list will be deleted
automatically.and progr
amming will return to the fist screen.
To savethe zonelist, enter O(No) to advance.
To savethe entire zonelist, enter O (No) md Progr
amming will return to the
first screen.
To deletea zoneor zonesin a zonelist enter 1 Wes) to advace.
Enter eachzoneto be deletedfrom the@ followedby the [*I key. After ~
zonesto be deletedare entered, enter 00 to return to the first screenso that
enotherlist canbe programmed,if desired.
Notes:
“ Any list may includeany or all of the system’szonenumbers.
. A zonelist canbe assignedto more than one output relay.
● If you only want to review what has been programmed previously enter
[#][8][1].The reviewcan be advancedby using the [*I key. when fishe~
enter [0][01* to quit. No programmed values canbe changedin this mode.
When programming
in *8O and *81 titiractive ~odes is completed,
exit the programming mode by keying w.
Unplug the AC transformer.