Vista Ademco -10SE Instrukcja Naprawy Strona 28

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 100
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 27
28–
Installing 5800 Series Transmitters
To be sure reception of the transmitter's signal at the proposed mounting location
is adequate, perform a Go/No Go test.
Go/No Go Test Mode
The Go/No Go tests will verify adequate RF signal strength from the proposed
transmitter location, and allow you to reorient or relocate transmitters if
necessary, before mounting the transmitters permanently.
This mode is similar to the transmitter test mode , except that the wireless
receiver gain is reduced. This will enable you to make sure that the RF signal
from each transmitter is received with sufficient signal amplitude when the
system is in the normal operating mode.
1. With at least one 2-line Alpha keypad (5137AD or 6139) connected to the
system, power up the system temporarily. If you had previously connected
the AC transformer to the control panel, you need only plug in the
transformer (to 120VAC outlet) to power up the system.
2. Enter installer code (4112) + [#] + 4 from partition 1's keypad. For multi-
partition systems, make sure all partitions are disarmed before entering this
mode.
3. Once you have placed transmitters in their desired locations and the
approximate length of wire to be run to sensors is connected to the
transmitter's screw terminals (if used), fault each transmitter. Do not conduct
this test with your hand wrapped around the transmitter as this will cause
inaccurate results.
Note: On button type transmitters whose buttons have been set to Arm
Away, Arm Stay, or Disarm, pressing a button will take the system out of the
Go/No Go Test mode and cause that action.
a. The keypad will beep three times to indicate signal reception and display
the appropriate zone number.
b. If the keypad does not beep, reorient or move the transmitter to another
location. Usually a few inches in either direction is all that is required.
4. If each transmitter produces the proper keypad response when it is faulted,
you can then permanently mount each of the transmitters according to the
instructions provided with them.
5. Exit the Go/No Go test mode by entering: Installer code (4112) + OFF.
6 Unplug the AC transformer.
Setting DIP switches on the 5827 Transmitter(s)
A 5827 transmitter must be set to the programmed House ID, using its DIP
switches.
5827 Wireless Keypad DIP Switch Table
1 2 3 4 5
ON
SWITCH UP FOR “ON”
SWITCH DOWN FOR “OFF”
HOUSE ID
SHOWN SET FOR HOUSE ID# 30
HOUSE
DIP SWITCH POSITION
ID
12345
1 –––UP
2 UP
3 UP UP
4–UP
5–UPUP
6–UPUP
7–UPUPUP
8 UP–––
9 UP UP
10 UP UP
11 UP UP UP
12 UP UP
13 UP UP UP
14 UP UP UP
15 UP UP UP UP
16 UP
HOUSE
DIP SWITCH POSITION
ID
1 2345
17 UP UP
18 UP UP
19 UP UP UP
20 UP UP
21 UP UP UP
22 UP UP UP
23 UP UP UP UP
24 UP UP
25 UP UP UP
26 UP UP UP
27 UP UP UP UP
28 UP UP UP
29 UP UP UP UP
30 UP UP UP UP
31 UP UP UP UP UP
Przeglądanie stron 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 99 100

Komentarze do niniejszej Instrukcji

Brak uwag